Digital Storage Oscilloscopes
TDS1000B Series • TDS2000B Series
Features & Benefits
·
40 MHz, 60 MHz, 100 MHz, and 200 MHz Bandwidths
·
Sample Rates up to 2 GS/s Real Time
·
2 or 4 Channels
·
Color or Monochrome LCD Display
·
Removable Data Storage via Front Panel USB Port
·
Seamless PC Connectivity via USB Device Port, with OpenChoice® and NI SignalExpress® PC Software
·
Advanced Triggers Including Pulse Width Trigger and Line-Selectable Video Trigger
·
FFT Standard on All Models
·
11 Automatic Measurements
·
Multiple Language User Interface and Context-sensitive Help
·
Direct Print to all PictBridge® Compatible Printers via USB Device Port
·
Lifetime Warranty *
1
Applications
·
Design and Debug
·
Education and Training
·
Manufacturing Test and Quality Control
·
Service and Repair
*
1
Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty
TDS1000B and TDS2000B Series Oscilloscopes
Instantly Productive. Incredibly Easy.
The TDS1000B and TDS2000B Series digital storage oscilloscopes deliver an unbeatable combination of performance and ease-of-use, at a price you can afford.
Affordable Digital Precision
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other color digital storage oscilloscope offers as much bandwidth and sample rate for the price. The TDS1000B and TDS2000B Series oscilloscopes provide accurate real-time acquisition up to their full bandwidth, the same record length at all time base settings, advanced triggers to isolate signals of interest, and 11 standard automatic measurements on all models. Their Fast Fourier Transform (FFT) and waveform add, subtract, and multiply math functions allow you to analyze, characterize, and troubleshoot circuits.
Quick and Easy Waveform Capture
The simple user interface with classic analog-style controls makes these instruments easy to use, reducing learning time and increasing efficiency. Innovative features such as the Auto set Menu, Probe Check Wizard, Context-Sensitive Help Menu and color LCD display (TDS2000B Series) optimize instrument setup and operation.
Flexible Data Transfer
With USB host and device ports which enable removable data storage, seamless PC connectivity, and direct printing, no other color or monochrome digital storage oscilloscope offers as much flexibility and ease of data transfer for the price.
Simple Documentation and Analysis
Easily capture, save and analyze measurement results with OpenChoice PC Communications Software. Simply pull screen images and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. To complement OpenChoice, National Instruments SignalExpress Tektronix Edition Software provides you with extended capabilities, including advanced analysis, remote oscilloscope control and live waveform analysis. Alternatively, if you prefer not to use the PC, you can simply print your image directly to any PictBridge compatible printer via the USB device port.
Performance You Can Count On
Depend on Tektronix to provide you with performance you can count on. In addition to industry leading service and support, every TDS1000B and TDS2000B Series oscilloscope comes backed with a Lifetime Warranty*
1
as standard.
Digital Storage Oscilloscopes
TDS1000B Series • TDS2000B Series
Ordering Information
TDS1001B: 40 MHz, 2 Ch, 500 MS/s, Monochrome DSO.
TDS1002B: 60 MHz, 2 Ch, 1 GS/s, Monochrome DSO.
TDS1012B: 100 MHz, 2 Ch, 1 GS/s, Monochrome DSO.
TDS2002B: 60 MHz, 2 Ch , 1 GS/s, Color DSO.
TDS2004B: 60 MHz, 4 Ch , 1 GS/s, Color DSO.
TDS2012B: 100 MHz, 2 Ch, 1 GS/s, Color DSO.
TDS2014B: 100 MHz, 4 Ch, 1 GS/s, Color DSO.
TDS2022B: 200 MHz, 2 Ch, 2 GS/s, Color DSO.
TDS2024B: 200 MHz, 4 Ch, 2 GS/s, Color DSO.
Standard Accessories
P2220 - 200 MHz 10x - 1x Switchable Passive Probes (one per channel).
Power Cord - (Please specify plug option).
NIM/NIST - Traceable Certificate of Calibration.
Documentation - User Manual (Please specify preferred language option).
OpenChoice PC Communications Software - Enables fast and easy communication between a Windows PC and the TDS1000B and TDS2000B Series via USB. Transfer and save settings, waveforms, measurements and screen images.
National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Base Version - A fully interactive measurement software environment optimized for the TDS1000B and TDS2000B Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using intuitive drag-and-drop user interface that does not require any programming. Standard TDS1000B and TDS2000B Series support for acquiring, controlling, viewing and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing and user-defined step capabilities. Order SIGEXPTE for permanent Professional Version capability.
Limited Lifetime Warranty *
3
covering labor and parts for defects in materials and workmanship for a minimum of 10 years, excluding probes and accessories*
4
.
*
3
Lifetime is defined as five years after Tektronix discontinues manufacturing the product, but the warranty length shall be at least ten years from date of original purchase. Lifetime warranty is non-transferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty.
International Power Plugs
Opt. A0 - North America power.
Opt. A1 - Universal EURO power.
Opt. A2 - United Kingdom power.
Opt. A3 - Australia power.
Opt. A5 - Switzerland power.
Opt. A6 - Japan power.
Opt. A10 - China power.
Opt. A11 - India power.
Opt. A99 - No power cord or AC adapter.
User Manual Options
Opt. L0 - English manual.
Opt. L1 - French manual.
Opt. L2 - Italian manual.
Opt. L3 - German manual.
Opt. L4 - Spanish manual.
Opt. L5 - Japanese manual.
Opt. L6 - Portuguese manual.
Opt. L7 - Simple Chinese manual.
Opt. L8 - Standard Chinese manual.
Opt. L9 - Korean manual.
Opt. L10 - Russian manual.
Translated front panel overlays included with their respective user manuals.
Recommended Accessories
TEK-USB-488 - GPIB to USB converter.
SIGEXPTE - National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Professional Version.
AC2100 - Soft Carrying Case for Instrument.
HCTEK4321 - Hard Plastic Carrying Case for Instrument (requires AC2100).
RM2000B - Rack Mount Kit.
071-1075-xx - Programmer Manual - English Only.
071-1828-xx - Service Manual - English Only.
TNGTDS01 - Operator Training Kit - Extensive instructions and step-by-step lab exercises provide education about the operation of TDS1000B and TDS2000B Series oscilloscopes. Kit includes self-paced CD-ROM based manual and signal source board.
174-4401-00 - USB host to device cable, 3 feet long.
Recommended Probes
P2220 - 10X to 1X Switchable Passive Probe (200 MHz when 10X is selected).
P6101B - 1X passive probe (15 MHz, 300 V
RMS
CAT II rating).
P6015A - 1000X high voltage passive probe (75 MHz).
P5100 - 100X high voltage passive probe (75 MHz).
P5200 - High voltage active differential probe (25 MHz).
P6021 - 15 A, 60 MHz AC current probe.
P6022 - 6 A, 120 MHz AC current probe.
A621 - 2000 A, 5 to 50 kHz AC current probe.
A622 - 100 A, 100 kHz AC/DC current probe/BNC.
TCP303/TCPA300 - 15 A, 15 MHz AC/DC current probe/amplifier.
TCP305/TCPA300 - 50 A, 50 MHz AC/DC current probe/amplifier.
TCP312/TCPA300 - 30 A, 100 MHz AC/DC current probe/amplifier.
TCP404XL/TCPA400 - 500 A, 2 MHz AC/DC current probe/amplifier.
Service Options *
4
Opt. C3 - Calibration Service 3 Years.
Opt. C5 - Calibration Service 5 Years.
Opt. D1 - Calibration Data Report.
Opt. D3 - Calibration Data Report 3 Years (with Option C3).
Opt. D5 - Calibration Data Report 5 Years (with Option C5).
Opt. CA1 - Provides a single calibration event or coverage for the designated calibration interval, whichever comes first.
*
4
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.
Service Offerings (available after purchase)
TDSxxxxB-CA1 - Provides a single calibration event or coverage for the designated calibration interval, whichever comes first.